title: "Everllence commercial heat pumps | Model and specs"
description: "Everllence builds transcritical CO₂ units for district heating and large water-heating loads."
image: "https://commercialheatpumpvendors.com/og.jpg"
url: "https://commercialheatpumpvendors.com/everllence/"
last_updated: "2026-11-28"
---

> Site index for agents: https://commercialheatpumpvendors.com/llms.txt

# Everllence

Everllence builds transcritical CO₂ units for district heating and large water-heating loads.

Water-to-water

Evidence reviewed 28 Nov 2026

[Visit supplier](https://www.everllence.com/) [Compare models](https://commercialheatpumpvendors.com/compare/?ids=everllence,scm-frigo,copeland-vilter,energy-machines) [Request quotes](https://commercialheatpumpvendors.com/everllence/#quote)

## Published specifications

Model or family

Product, family or configuration covered by the cited specification.

TCC HPU28 [1](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf "Source for Model or family: www.everllence.com, accessed 2026-11-28")

Heat path

Where the system picks up heat and where it delivers it.

Water-to-water [2](https://www.everllence.com/our-focus/lighthouse-projects/esbjerg-heat-pump "Source for Heat path: www.everllence.com, accessed 2026-11-28")

Rated heat output kW

Heating output at the stated rating point. Read with Rating conditions.

9,670 [1](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf "Source for Rated heat output: www.everllence.com, accessed 2026-11-28")

Rating conditions

Test temperatures, standard or equipment configuration for the adjacent output.

Source 10 °C; sink supply/return 110/40 °C [1](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf "Source for Rating conditions: www.everllence.com, accessed 2026-11-28")

Published delivery temperature °C

Published delivery temperature or limit. Read with Temperature conditions and the linked product sheet.

150 [1](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf "Source for Published delivery temperature: www.everllence.com, accessed 2026-11-28")

Refrigerant

Working fluid for the cited model or options for the cited family.

R744 [1](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf "Source for Refrigerant: www.everllence.com, accessed 2026-11-28")

Documented use

Building or process application described in the source.

District heating [1](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf "Source for Documented use: www.everllence.com, accessed 2026-11-28")

Second-source evidence

What an independent publisher establishes about the maker, model or installation.

IEA HPT Project 68 technology review names Everllence Transcritical CO2 [3](https://heatpumpingtechnologies.org/project68/task1/ "Source for Second-source evidence: heatpumpingtechnologies.org, accessed 2026-11-28")

Delivery medium

Shortlist group derived from the documented output medium or process duty.

Water [2](https://www.everllence.com/our-focus/lighthouse-projects/esbjerg-heat-pump "Source for Delivery medium: www.everllence.com, accessed 2026-11-28")

Match scope

Directory classification of the independent match, using brand and model identifiers where available.

Named product family [3](https://heatpumpingtechnologies.org/project68/task1/ "Source for Match scope: heatpumpingtechnologies.org, accessed 2026-11-28")

## Evidence

1.  [www.everllence.com](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf) accessed 2026-11-28
2.  [www.everllence.com](https://www.everllence.com/our-focus/lighthouse-projects/esbjerg-heat-pump) accessed 2026-11-28
3.  [heatpumpingtechnologies.org](https://heatpumpingtechnologies.org/project68/task1/) accessed 2026-11-28

Send your peak heating load, heat source, supply and return temperatures, project location, electrical supply and target delivery date.

## Request quotes at your design point

One brief, several replies: Commercial Heat Pump Vendors forwards it to the heat pump suppliers that fit and they answer you directly.

Brief received by Commercial Heat Pump Vendors. Matching heat pump suppliers reply to your inbox.

We couldn't send your request through Commercial Heat Pump Vendors. Check your email address and try again, or write to [hello@commercialheatpumpvendors.com](mailto:hello@commercialheatpumpvendors.com).

```json
{"@context":"https://schema.org","@graph":[{"@type":"Organization","@id":"https://commercialheatpumpvendors.com/everllence/#org","name":"Everllence","url":"https://www.everllence.com/","description":"Everllence builds transcritical CO₂ units for district heating and large water-heating loads.","subjectOf":{"@type":"WebPage","url":"https://commercialheatpumpvendors.com/everllence/","dateModified":"2026-11-28"}},{"@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Vendor directory","item":"https://commercialheatpumpvendors.com/"},{"@type":"ListItem","position":2,"name":"Everllence","item":"https://commercialheatpumpvendors.com/everllence/"}]}]}
```