# Which commercial heat pumps supply water at 80 °C or higher?

19 vendors document a catalogued water delivery temperature of at least 80 °C for an equipment family or model. Use the cited operating envelope to identify candidates and ask for net heating output at your source temperature and required return temperature. Examples include [Advansor](https://commercialheatpumpvendors.com/advansor/), [Everllence](https://commercialheatpumpvendors.com/everllence/) and [Fenagy](https://commercialheatpumpvendors.com/fenagy/).

[Field definitions and sources](https://commercialheatpumpvendors.com/methodology/) [Full vendor table](https://commercialheatpumpvendors.com/#vendors)

| Name | Model or family | Heat path | Published delivery temperature °C | Temperature conditions | Refrigerant | Verified |
| --- | --- | --- | --- | --- | --- | --- |
| [Advansor](https://commercialheatpumpvendors.com/advansor/) | ValueBox 600 | Air-to-water | 95[3](https://www.advansor.com/product/valuebox "Source: www.advansor.com (accessed 2026-11-28)") | Family maximum; published 600 kW installation uses 40/80 °C water at −5 °C ambient | R744 | 2026-11-28 |
| [Everllence](https://commercialheatpumpvendors.com/everllence/) | TCC HPU28 | Water-to-water | 150[1](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf "Source: www.everllence.com (accessed 2026-11-28)") | — | R744 | 2026-11-28 |
| [Fenagy](https://commercialheatpumpvendors.com/fenagy/) | H-600 (H-range) | Air-to-water and Water-to-water | 85[1](https://www.fenagy.dk/en/heat-pumps-h-range "Source: www.fenagy.dk (accessed 2026-11-28)") | Below 45 °C return (family application guidance) | R744 | 2026-11-28 |
| [Flow Environmental Systems](https://commercialheatpumpvendors.com/flow-environmental/) | ANSWR Model C | Air- or water-to-water | 82.2[2](https://www.flowenvirosys.com/_files/ugd/5d8673_4e7fcfc354614d6388a2fc84313adcde.pdf "Source: www.flowenvirosys.com (accessed 2026-11-28)") | Boiler-mode leaving water, with 140 °F entering water in the cited table | R744 | 2026-11-28 |
| [Friotherm](https://commercialheatpumpvendors.com/friotherm/) | Unitop | Water-to-water | 120[1](https://heatpumpingtechnologies.org/content/uploads/sites/70/2023/09/annex-58-task-1-technologies-task-report.pdf "Source: heatpumpingtechnologies.org (accessed 2026-11-28)") | — | — | 2026-11-28 |
| [Galletti](https://commercialheatpumpvendors.com/galletti/) | WBE | Water-to-water | 90[1](https://www.galletti.com/en/products/chillers_and_heat_pumps_564/dissipation-with-water/wbe/ "Source: www.galletti.com (accessed 2026-11-28)") | Typically 45 °C source water for high-temperature production | R515B | 2026-11-28 |
| [HEATEN](https://commercialheatpumpvendors.com/heaten/) | HeatBooster HBL4-W/W | Water-to-water | 200[1](https://heaten.com/products "Source: heaten.com (accessed 2026-11-28)") | — | Hydrocarbon or HFO configuration | 2026-11-28 |
| [HiRef](https://commercialheatpumpvendors.com/hiref/) | KSW | Water-to-water | 80[2](https://hiref.com/news/water-to-water-heat-ps-ksw-range "Source: hiref.com (accessed 2026-11-28)") | 80 °C with a medium-temperature water source | — | 2026-11-28 |
| [Johnson Controls / Sabroe](https://commercialheatpumpvendors.com/johnson-controls-sabroe/) | HitemHP | Waste heat-to-water | 122[1](https://www.sabroe.com/products-and-solutions/industrial-heat-pumps/recip-heat-pump/hitemhp_ir/hitemhp-heat-pump "Source: www.sabroe.com (accessed 2026-11-28)") | — | R600 / R600a | 2026-11-28 |
| [Lync by Watts](https://commercialheatpumpvendors.com/lync/) | Aegis A 250 | Air-to-water | 82[3](https://www.lyncbywatts.com/dfsmedia/0533dbba17714b1ab581ab07a4cbb521/182753-source/639119477290000000/aegis-brochure "Source: www.lyncbywatts.com (accessed 2026-11-28)") | Primary outlet range 60–82 °C; storage range depends on heat exchanger module | R744 | 2026-11-28 |
| [Mayekawa](https://commercialheatpumpvendors.com/mayekawa/) | unimo AW | Air-to-water | 90[1](https://americas.mayekawa.com/mna/products/heat-pumps/ "Source: americas.mayekawa.com (accessed 2026-11-28)") | — | R744 | 2026-11-28 |
| [Mitsubishi Heavy Industries Thermal Systems](https://commercialheatpumpvendors.com/mitsubishi-heavy-industries/) | ETW-S | Water-to-water | 130[1](https://heatpumpingtechnologies.org/content/uploads/sites/70/2022/07/technologymhietw-s.pdf "Source: heatpumpingtechnologies.org (accessed 2026-11-28)") | — | R134a | 2026-11-28 |
| [OCHSNER Energietechnik](https://commercialheatpumpvendors.com/ochsner/) | IWWDS 430 R4b | Water-to-water | 130[1](https://heatpumpingtechnologies.org/content/uploads/sites/70/2024/05/20240522annex58templatesuppliertechnologyrev3iwwdstechnology-003.pdf "Source: heatpumpingtechnologies.org (accessed 2026-11-28)") | — | R1233zd | 2026-11-28 |
| [Oilon](https://commercialheatpumpvendors.com/oilon/) | ChillHeat P30–P450 | Waste heat-to-water | 120[3](https://oilon.com/wp-content/uploads/2024/04/Oilon_ChillHeat-EN.pdf "Source: oilon.com (accessed 2026-11-28)") | — | R134a for B0/W35 range figures | 2026-11-28 |
| [Rank ORC](https://commercialheatpumpvendors.com/rank/) | HP (HTHP series) | Brine-to-water | 150[1](https://www.grosswaermepumpen-info.de/en-us/products/product/rank-hp/ "Source: www.grosswaermepumpen-info.de (accessed 2026-11-28)") | Portal lists 25–110 °C source envelope, with separate flow limits | R1233zd(E) / R1336mzz(Z) / R245fa | 2026-11-28 |
| [SCM Frigo](https://commercialheatpumpvendors.com/scm-frigo/) | SMART SHP W110 | Water-to-water | 85[4](https://www.smartheatpump.com/s/SMARTHP_BROCHURE_UK.pdf "Source: www.smartheatpump.com (accessed 2026-11-28)") | — | R744 | 2026-11-28 |
| [Siemens Energy](https://commercialheatpumpvendors.com/siemens-energy/) | High-temperature industrial heat pump | Waste heat-to-water | 150[1](https://assets.siemens-energy.com/dam/4135a8d2-4131-4317-94f4-b0530189299e/Heatpump-Interactive-Brochure-pdf_Original%20file.pdf "Source: assets.siemens-energy.com (accessed 2026-11-28)") | — | — | 2026-11-28 |
| [SKADEC](https://commercialheatpumpvendors.com/skadec/) | SH.F. R600 | Water-to-water | 90[3](https://skadec.de/en/products/water-cooled-high-temperature-heat-pumps-with-natural-refrigerant-r600a/ "Source: skadec.de (accessed 2026-11-28)") | — | R600a | 2026-11-28 |
| [Star Refrigeration](https://commercialheatpumpvendors.com/star-refrigeration/) | Water Source Neatpump | Water-to-water | 130[1](https://www.star-ref.co.uk/products/heat-pumps/water-source-heat-pump-neatpump/ "Source: www.star-ref.co.uk (accessed 2026-11-28)") | — | R717 | 2026-11-28 |

Send your peak heating load, heat source, supply and return temperatures, project location, electrical supply and target delivery date.

## Request quotes at your design point

One brief, several replies: Commercial Heat Pump Vendors forwards it to the heat pump suppliers that fit and they answer you directly.

Brief received by Commercial Heat Pump Vendors. Matching heat pump suppliers reply to your inbox.

We couldn't send your request through Commercial Heat Pump Vendors. Check your email address and try again, or write to [hello@commercialheatpumpvendors.com](mailto:hello@commercialheatpumpvendors.com).

## Questions for your RFQ

### What is the temperature threshold for this table?

The table uses a published water delivery figure of 80 °C or higher. Follow the value to the product document for the applicable operating conditions.

### What should I ask for on a boiler retrofit?

Request the net heat output at your required supply temperature, design return temperature and coldest source condition. Ask for the control sequence at part load.

### Which delivery temperature should I use with an indirect water heater?

Use the temperature required on the load side of the heat exchanger. Ask the vendor to state the primary-loop and load-side temperatures separately.

```json
{"@context":"https://schema.org","@graph":[{"@type":"ItemList","@id":"https://commercialheatpumpvendors.com/high-temperature-water/#list","name":"Heat pumps with 80 °C water delivery","numberOfItems":19,"itemListOrder":"https://schema.org/ItemListUnordered","itemListElement":[{"@type":"ListItem","position":1,"name":"Advansor","url":"https://commercialheatpumpvendors.com/advansor/"},{"@type":"ListItem","position":2,"name":"Everllence","url":"https://commercialheatpumpvendors.com/everllence/"},{"@type":"ListItem","position":3,"name":"Fenagy","url":"https://commercialheatpumpvendors.com/fenagy/"},{"@type":"ListItem","position":4,"name":"Flow Environmental Systems","url":"https://commercialheatpumpvendors.com/flow-environmental/"},{"@type":"ListItem","position":5,"name":"Friotherm","url":"https://commercialheatpumpvendors.com/friotherm/"},{"@type":"ListItem","position":6,"name":"Galletti","url":"https://commercialheatpumpvendors.com/galletti/"},{"@type":"ListItem","position":7,"name":"HEATEN","url":"https://commercialheatpumpvendors.com/heaten/"},{"@type":"ListItem","position":8,"name":"HiRef","url":"https://commercialheatpumpvendors.com/hiref/"},{"@type":"ListItem","position":9,"name":"Johnson Controls / Sabroe","url":"https://commercialheatpumpvendors.com/johnson-controls-sabroe/"},{"@type":"ListItem","position":10,"name":"Lync by Watts","url":"https://commercialheatpumpvendors.com/lync/"},{"@type":"ListItem","position":11,"name":"Mayekawa","url":"https://commercialheatpumpvendors.com/mayekawa/"},{"@type":"ListItem","position":12,"name":"Mitsubishi Heavy Industries Thermal Systems","url":"https://commercialheatpumpvendors.com/mitsubishi-heavy-industries/"},{"@type":"ListItem","position":13,"name":"OCHSNER Energietechnik","url":"https://commercialheatpumpvendors.com/ochsner/"},{"@type":"ListItem","position":14,"name":"Oilon","url":"https://commercialheatpumpvendors.com/oilon/"},{"@type":"ListItem","position":15,"name":"Rank ORC","url":"https://commercialheatpumpvendors.com/rank/"},{"@type":"ListItem","position":16,"name":"SCM Frigo","url":"https://commercialheatpumpvendors.com/scm-frigo/"},{"@type":"ListItem","position":17,"name":"Siemens Energy","url":"https://commercialheatpumpvendors.com/siemens-energy/"},{"@type":"ListItem","position":18,"name":"SKADEC","url":"https://commercialheatpumpvendors.com/skadec/"},{"@type":"ListItem","position":19,"name":"Star Refrigeration","url":"https://commercialheatpumpvendors.com/star-refrigeration/"}]},{"@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Vendor directory","item":"https://commercialheatpumpvendors.com/"},{"@type":"ListItem","position":2,"name":"Heat pumps with 80 °C water delivery","item":"https://commercialheatpumpvendors.com/high-temperature-water/"}]}]}
```