agent:
  instructions: "Use this search API to find relevant content across this site with keywords or natural-language queries, instead of crawling individual pages. Results are returned in Markdown."
  endpoint: "https://commercialheatpumpvendors.com/.well-known/search?q={query}"
  method: "GET"
  documentation: "https://developers.cloudflare.com/ai-search/how-to/search-for-agents/"
title: "Commercial Heat Pumps | Compare 64 Vendors"
description: "Shortlist commercial heat pumps by heat source, refrigerant and water temperature. Compare manufacturer ratings, open the evidence and request project quotes."
image: "https://commercialheatpumpvendors.com/og.jpg"
url: "https://commercialheatpumpvendors.com/"
last_updated: "2026-11-28"
---

> Site index for agents: https://commercialheatpumpvendors.com/llms.txt

# Commercial heat pumps

Find the heat pump that meets your design point.

Compare [64](https://commercialheatpumpvendors.com/#vendors) commercial heat pump vendors, including [33](https://commercialheatpumpvendors.com/air-to-water/) with documented air-to-water equipment. Shortlist by heat source, delivery temperature and refrigerant, then open the manufacturer data and independent evidence for each entry. Send the same load, temperatures and electrical supply to your shortlisted vendors so their quotes address the same design point.

[Evidence reviewed 28 Nov 2026](https://commercialheatpumpvendors.com/methodology/#coverage) [CSV](https://commercialheatpumpvendors.com/data.csv) [JSON](https://commercialheatpumpvendors.com/data.json)

| Name | Model or family | Heat path | Published heat output | Rated heat output kW | Published delivery temperature °C | Refrigerant | Verified |
| --- | --- | --- | --- | --- | --- | --- | --- |
| [A. O. Smith](https://commercialheatpumpvendors.com/ao-smith/) | CAHP-120 100 | Air-to-water | — | — | 65.6[1](https://assets.hotwater.com/damroot/Original/10003/AOSZE55000.pdf "Source: assets.hotwater.com (accessed 2026-11-28)") | R134a | 2026-11-28 |
| [Advansor](https://commercialheatpumpvendors.com/advansor/) | ValueBox 600 | Air-to-water | 600 kW (published project capacity) | — | 95[3](https://www.advansor.com/product/valuebox "Source: www.advansor.com (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Aermec](https://commercialheatpumpvendors.com/aermec/) | PRM 0504 | Air-to-water | — | 101.7[2](https://global.aermec.com/wp-content/uploads/2026/02/Aermec_PRM_01_EN.pdf "Source: global.aermec.com (accessed 2026-11-28)") | 75[2](https://global.aermec.com/wp-content/uploads/2026/02/Aermec_PRM_01_EN.pdf "Source: global.aermec.com (accessed 2026-11-28)") | R290 | 2026-11-28 |
| [Carrier](https://commercialheatpumpvendors.com/carrier/) | AquaSnap 61AQ | Air-to-water | 40–130 kW nominal heating, 61AQ family | — | 75[2](https://www.carrier.com/commercial/en/eu/products/heating-air-conditioning/air-to-water-heat-pumps/61aq/ "Source: www.carrier.com (accessed 2026-11-28)") | R290 | 2026-11-28 |
| [Clade Engineering Systems](https://commercialheatpumpvendors.com/clade/) | Acer 2 | Air-to-water | — | 130[2](https://clade-es.com/products/commercial-heat-pumps/acer-2-co2-range/acer-2-heat-pump/ "Source: clade-es.com (accessed 2026-11-28)") | 70[2](https://clade-es.com/products/commercial-heat-pumps/acer-2-co2-range/acer-2-heat-pump/ "Source: clade-es.com (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Clivet](https://commercialheatpumpvendors.com/clivet/) | SHEEN PRO (WiSAN-PSE1 10.1–45.2) | Air-to-water | 25–55 kW (family product-page capacity) | — | 77[1](https://www.clivet.com/en/products/commercial-and-industrial/heat-pumps-and-chillers/sheen-pro-wisan-pse1-10.1-45.2-r-290 "Source: www.clivet.com (accessed 2026-11-28)") | R290 | 2026-11-28 |
| [Colmac WaterHeat](https://commercialheatpumpvendors.com/colmac-waterheat/) | CxV series | Air-to-water | — | — | — | R454B | 2026-11-28 |
| [COMBITHERM](https://commercialheatpumpvendors.com/combitherm/) | High Temperature Heat Pumps | Waste heat-to-process heat | 20–1,000 kW across the manufacturer range | — | — | HFO / HFC or non-halogenated configuration | 2026-11-28 |
| [Copeland / Vilter](https://commercialheatpumpvendors.com/copeland-vilter/) | Vilter VQ95 | Water-to-water | 1–5 MW on one skid | — | — | R717 | 2026-11-28 |
| [Daikin](https://commercialheatpumpvendors.com/daikin/) | EWYT-B | Air-to-water | 85–640 kW heating, EWYT-B installation manual range | — | — | R32 | 2026-11-28 |
| [ECO₂ Systems](https://commercialheatpumpvendors.com/eco2-systems/) | SANCO₂ GS5-45HPC | Air-to-water | 4.5 kW nominal per heat pump | — | 62.8[1](https://eco2waterheater.com/wp-content/uploads/2025/10/SANCO2-GS5-Installation-Manual-20962971.pdf "Source: eco2waterheater.com (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [ecop Technologies](https://commercialheatpumpvendors.com/ecop/) | Rotation Heat Pump | Waste heat-to-process heat | 700 kW per core; 5.6 MW illustrated with eight cores | — | — | ecop fluid 1 | 2026-11-28 |
| [ELCO](https://commercialheatpumpvendors.com/elco/) | AEROTOP EVO LN 105 | Air-to-water | — | 81.9[1](https://www.elco.co.uk/products/renewables/aerotop-evo.html "Source: www.elco.co.uk (accessed 2026-11-28)") | — | — | 2026-11-28 |
| [Energy Machines](https://commercialheatpumpvendors.com/energy-machines/) | EMT 1380-1-4-ECO | Water-to-water | — | 476[3](https://heatpumps.energymachines.com/uploads/Datasheet_EMT_1380-1-4_7.pdf "Source: heatpumps.energymachines.com (accessed 2026-11-28)") | — | R1234ze | 2026-11-28 |
| [Enerin](https://commercialheatpumpvendors.com/enerin/) | HoegTemp | Waste heat-to-steam | 250–1,000 kW per module | — | 250[1](https://www.enerin.no/hoegtemp "Source: www.enerin.no (accessed 2026-11-28)") | R704 | 2026-11-28 |
| [Everllence](https://commercialheatpumpvendors.com/everllence/) | TCC HPU28 | Water-to-water | — | 9,670[1](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf "Source: www.everllence.com (accessed 2026-11-28)") | 150[1](https://www.everllence.com/docs/default-source/heat-pumps/evr-000004en_l3_tcc-heat-pump_es_preview.pdf "Source: www.everllence.com (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Fenagy](https://commercialheatpumpvendors.com/fenagy/) | H-600 (H-range) | Air-to-water and Water-to-water | 600 kW (catalog capacity per unit) | — | 85[1](https://www.fenagy.dk/en/heat-pumps-h-range "Source: www.fenagy.dk (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Flow Environmental Systems](https://commercialheatpumpvendors.com/flow-environmental/) | ANSWR Model C | Air- or water-to-water | — | 66.8[2](https://www.flowenvirosys.com/_files/ugd/5d8673_4e7fcfc354614d6388a2fc84313adcde.pdf "Source: www.flowenvirosys.com (accessed 2026-11-28)") | 82.2[2](https://www.flowenvirosys.com/_files/ugd/5d8673_4e7fcfc354614d6388a2fc84313adcde.pdf "Source: www.flowenvirosys.com (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Friotherm](https://commercialheatpumpvendors.com/friotherm/) | Unitop | Water-to-water | 3–35 MW across custom single- and two-stage systems | — | 120[1](https://heatpumpingtechnologies.org/content/uploads/sites/70/2023/09/annex-58-task-1-technologies-task-report.pdf "Source: heatpumpingtechnologies.org (accessed 2026-11-28)") | — | 2026-11-28 |
| [Futraheat](https://commercialheatpumpvendors.com/futraheat/) | Greensteam | Waste heat-to-steam | Up to 400 kW thermal per unit | — | — | R1233zd in the Greensteam 330 brewery installation | 2026-11-28 |
| [Galletti](https://commercialheatpumpvendors.com/galletti/) | WBE | Water-to-water | 45–220 kW (family catalog range) | — | 90[1](https://www.galletti.com/en/products/chillers_and_heat_pumps_564/dissipation-with-water/wbe/ "Source: www.galletti.com (accessed 2026-11-28)") | R515B | 2026-11-28 |
| [GENERAL (formerly Fujitsu General)](https://commercialheatpumpvendors.com/general-airstage/) | AIRSTAGE VU-7 | Air-to-air | 6–32 ton VRF system range | — | — | R32 | 2026-11-28 |
| [GKT](https://commercialheatpumpvendors.com/gkt/) | CompriVAP | Waste heat-to-steam | Up to 47 MW thermal for the BASF Ludwigshafen project | — | — | — | 2026-11-28 |
| [HEATEN](https://commercialheatpumpvendors.com/heaten/) | HeatBooster HBL4-W/W | Water-to-water | 0.8–2.5 MW thermal, HBL4-W/W envelope | — | 200[1](https://heaten.com/products "Source: heaten.com (accessed 2026-11-28)") | Hydrocarbon or HFO configuration | 2026-11-28 |
| [HiRef](https://commercialheatpumpvendors.com/hiref/) | KSW | Water-to-water | Up to 180 kW (single circuit) | — | 80[2](https://hiref.com/news/water-to-water-heat-ps-ksw-range "Source: hiref.com (accessed 2026-11-28)") | — | 2026-11-28 |
| [Intellihot](https://commercialheatpumpvendors.com/intellihot/) | Electron iE6 | Air-to-water | Up to 300,000 Btu/h for the iE6 | — | — | R744 | 2026-11-28 |
| [Johnson Controls / Sabroe](https://commercialheatpumpvendors.com/johnson-controls-sabroe/) | HitemHP | Waste heat-to-water | 100–1,000 kW across the range | — | 122[1](https://www.sabroe.com/products-and-solutions/industrial-heat-pumps/recip-heat-pump/hitemhp_ir/hitemhp-heat-pump "Source: www.sabroe.com (accessed 2026-11-28)") | R600 / R600a | 2026-11-28 |
| [Keyter](https://commercialheatpumpvendors.com/keyter/) | ZIRAN PRO KWR | Air-to-water | 41–253 kW (published thermal power, reversible and cooling-only units) | — | — | R290 | 2026-11-28 |
| [Kobelco](https://commercialheatpumpvendors.com/kobelco/) | Steam Grow Heat Pump SGH120 | Water-to-steam | — | 370[1](https://heatpumpingtechnologies.org/content/uploads/sites/70/2022/07/technologykobelcosgh120-1.pdf "Source: heatpumpingtechnologies.org (accessed 2026-11-28)") | — | R245fa | 2026-11-28 |
| [Laars Heating Systems](https://commercialheatpumpvendors.com/laars/) | E-Therm ECHV0325 | Air-to-water | — | 95[2](https://www.laars.com/uploads/products/Laars-0126-ETherm-2185B.pdf "Source: www.laars.com (accessed 2026-11-28)") | — | R744 | 2026-11-28 |
| [LG Electronics](https://commercialheatpumpvendors.com/lg/) | Multi V i ZRUM096DTE6 | Air-to-air | 103,000 BTU/h high heating at 47°F, ducted rating shown in LG submittal | — | — | R32 | 2026-11-28 |
| [Lochinvar](https://commercialheatpumpvendors.com/lochinvar/) | Veritus AHP140 | Air-to-water | 136,881 BTU/h maximum output under DOE test conditions | 40.1[3](https://assets.lochinvar.com/damroot/Original/10014/VAHP-04.pdf "Source: assets.lochinvar.com (accessed 2026-11-28)") | — | R513A | 2026-11-28 |
| [Lync by Watts](https://commercialheatpumpvendors.com/lync/) | Aegis A 250 | Air-to-water | — | 61.5[3](https://www.lyncbywatts.com/dfsmedia/0533dbba17714b1ab581ab07a4cbb521/182753-source/639119477290000000/aegis-brochure "Source: www.lyncbywatts.com (accessed 2026-11-28)") | 82[3](https://www.lyncbywatts.com/dfsmedia/0533dbba17714b1ab581ab07a4cbb521/182753-source/639119477290000000/aegis-brochure "Source: www.lyncbywatts.com (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Mayekawa](https://commercialheatpumpvendors.com/mayekawa/) | unimo AW | Air-to-water | — | 74[1](https://americas.mayekawa.com/mna/products/heat-pumps/ "Source: americas.mayekawa.com (accessed 2026-11-28)") | 90[1](https://americas.mayekawa.com/mna/products/heat-pumps/ "Source: americas.mayekawa.com (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Mitsubishi Electric](https://commercialheatpumpvendors.com/mitsubishi-electric/) | Heat2O QAHV-N136TAU-HPB | Air-to-water | — | 40[2](https://dw2p0k56b2hr9.cloudfront.net/ME_CM_2919_9_25_Heat2_O_Marketing_Brochure_02e1b20ef6.pdf "Source: dw2p0k56b2hr9.cloudfront.net (accessed 2026-11-28)") | 71.1[2](https://dw2p0k56b2hr9.cloudfront.net/ME_CM_2919_9_25_Heat2_O_Marketing_Brochure_02e1b20ef6.pdf "Source: dw2p0k56b2hr9.cloudfront.net (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Mitsubishi Heavy Industries Thermal Systems](https://commercialheatpumpvendors.com/mitsubishi-heavy-industries/) | ETW-S | Water-to-water | — | 627[1](https://heatpumpingtechnologies.org/content/uploads/sites/70/2022/07/technologymhietw-s.pdf "Source: heatpumpingtechnologies.org (accessed 2026-11-28)") | 130[1](https://heatpumpingtechnologies.org/content/uploads/sites/70/2022/07/technologymhietw-s.pdf "Source: heatpumpingtechnologies.org (accessed 2026-11-28)") | R134a | 2026-11-28 |
| [MTA](https://commercialheatpumpvendors.com/mta/) | iCYGNUS N HP 019 | Air-to-water | — | 66.3[2](https://www.mta-it.com/backend/prodotti/file_upload/allegato/2603261045111_5050dcyny001cb_0226_lr.pdf "Source: www.mta-it.com (accessed 2026-11-28)") | 78[3](https://www.mta-it.com/eng/products/heat-pumps-systems/air-cooled-heat-pumps/icygnus-n-hp.php "Source: www.mta-it.com (accessed 2026-11-28)") | R290 | 2026-11-28 |
| [Multistack](https://commercialheatpumpvendors.com/multistack/) | ARP | Air-to-water | 10–600 ton system range across linked modules, manufacturer listing | — | — | — | 2026-11-28 |
| [Nyle Water Heating Systems](https://commercialheatpumpvendors.com/nyle/) | C90A | Air-to-water | 95,500 BTU/h nominal DOE capacity | 26.4[3](https://files.heatwater.com/heatwater/uploads/2023/09/01132339/SB-C90A-092724.pdf "Source: files.heatwater.com (accessed 2026-11-28)") | 68.3[3](https://files.heatwater.com/heatwater/uploads/2023/09/01132339/SB-C90A-092724.pdf "Source: files.heatwater.com (accessed 2026-11-28)") | R513A | 2026-11-28 |
| [OCHSNER Energietechnik](https://commercialheatpumpvendors.com/ochsner/) | IWWDS 430 R4b | Water-to-water | 500 kW heat supply capacity in Annex 58 exhibit | — | 130[1](https://heatpumpingtechnologies.org/content/uploads/sites/70/2024/05/20240522annex58templatesuppliertechnologyrev3iwwdstechnology-003.pdf "Source: heatpumpingtechnologies.org (accessed 2026-11-28)") | R1233zd | 2026-11-28 |
| [Oilon](https://commercialheatpumpvendors.com/oilon/) | ChillHeat P30–P450 | Waste heat-to-water | 30–450 kW at B0/W35 with R134a | — | 120[3](https://oilon.com/wp-content/uploads/2024/04/Oilon_ChillHeat-EN.pdf "Source: oilon.com (accessed 2026-11-28)") | R134a for B0/W35 range figures | 2026-11-28 |
| [Olvondo Technology](https://commercialheatpumpvendors.com/olvondo-technology/) | HighLift | Waste heat-to-steam | 750 kW rated output | — | — | R704 | 2026-11-28 |
| [Panasonic](https://commercialheatpumpvendors.com/panasonic/) | Big Aquarea T-CAP WH-WXG30ME8 | Air-to-water | — | 30[2](https://web.media.panasonic.eu/public/EU_CATALOGUES_IMAGES_BACKGROUNDS/2025/PDF%20to%20WEB/EU%2020P%20BIG%20AQUAREA%20M%2025%20LR.pdf "Source: web.media.panasonic.eu (accessed 2026-11-28)") | 75[2](https://web.media.panasonic.eu/public/EU_CATALOGUES_IMAGES_BACKGROUNDS/2025/PDF%20to%20WEB/EU%2020P%20BIG%20AQUAREA%20M%2025%20LR.pdf "Source: web.media.panasonic.eu (accessed 2026-11-28)") | R290 | 2026-11-28 |
| [PILLER](https://commercialheatpumpvendors.com/piller/) | PILLER Industrial Heat Pump | Waste heat-to-steam | 10 MW in the IEA EPDM rubber stripper case | — | — | R718 in the IEA EPDM case | 2026-11-28 |
| [Qpinch](https://commercialheatpumpvendors.com/qpinch/) | Qpinch Heat Transformer | Waste heat-to-steam | 0.5 MW nominal smallest standard unit; 15 MW largest engineered design | — | — | Water / phosphoric acid | 2026-11-28 |
| [Qvantum](https://commercialheatpumpvendors.com/qvantum/) | QA50 | Air-to-water | — | 50[3](https://www.qvantum.com/wp-content/uploads/2026/11/QA50_Qvantum_UK_1.pdf "Source: www.qvantum.com (accessed 2026-11-28)") | 70[3](https://www.qvantum.com/wp-content/uploads/2026/11/QA50_Qvantum_UK_1.pdf "Source: www.qvantum.com (accessed 2026-11-28)") | R290 | 2026-11-28 |
| [Rank ORC](https://commercialheatpumpvendors.com/rank/) | HP (HTHP series) | Brine-to-water | 250–600 kW (portal thermal capacities; model-specific rating point unpublished) | — | 150[1](https://www.grosswaermepumpen-info.de/en-us/products/product/rank-hp/ "Source: www.grosswaermepumpen-info.de (accessed 2026-11-28)") | R1233zd(E) / R1336mzz(Z) / R245fa | 2026-11-28 |
| [Rheem](https://commercialheatpumpvendors.com/rheem/) | HPHD-60VNU-201 | Air-to-water | Up to 84,752 BTU/h heating (110°F air and 100°F leaving water) | — | 65.6[3](https://files.rheem.com/blobazrheem/wp-content/uploads/sites/2/HPWHSS-101-Rev-3-Hulk-Commercial-HPWH-Trade-Brochure_0209.pdf "Source: files.rheem.com (accessed 2026-11-28)") | R134a | 2026-11-28 |
| [Rhoss](https://commercialheatpumpvendors.com/rhoss/) | POKER-P THAETP 250 | Air-to-water | 47.4–190.5 kW (one to four modules) | 47.4[2](https://www.rhoss.it/products/thaetp-250/ "Source: www.rhoss.it (accessed 2026-11-28)") | 75[2](https://www.rhoss.it/products/thaetp-250/ "Source: www.rhoss.it (accessed 2026-11-28)") | R290 | 2026-11-28 |
| [Samsung](https://commercialheatpumpvendors.com/samsung/) | DVM S2 AM100AXVAGH/EU | Air-to-air | 31.5 kW rated heating for AM100AXVAGH/EU, Samsung technical data book | — | — | R410A | 2026-11-28 |
| [SCM Frigo](https://commercialheatpumpvendors.com/scm-frigo/) | SMART SHP W110 | Water-to-water | — | 109[4](https://www.smartheatpump.com/s/SMARTHP_BROCHURE_UK.pdf "Source: www.smartheatpump.com (accessed 2026-11-28)") | 85[4](https://www.smartheatpump.com/s/SMARTHP_BROCHURE_UK.pdf "Source: www.smartheatpump.com (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Siemens Energy](https://commercialheatpumpvendors.com/siemens-energy/) | High-temperature industrial heat pump | Waste heat-to-water | Up to 70 MW thermal | — | 150[1](https://assets.siemens-energy.com/dam/4135a8d2-4131-4317-94f4-b0530189299e/Heatpump-Interactive-Brochure-pdf_Original%20file.pdf "Source: assets.siemens-energy.com (accessed 2026-11-28)") | — | 2026-11-28 |
| [SKADEC](https://commercialheatpumpvendors.com/skadec/) | SH.F. R600 | Water-to-water | 400–2,200 kW (SH.F. catalog heating range) | — | 90[3](https://skadec.de/en/products/water-cooled-high-temperature-heat-pumps-with-natural-refrigerant-r600a/ "Source: skadec.de (accessed 2026-11-28)") | R600a | 2026-11-28 |
| [Spilling](https://commercialheatpumpvendors.com/spilling/) | Spilling steam compressor | Steam-to-steam | Approximately 1–20 t/h steam flow | — | — | R718 in reviewed Spilling Steam Compressor | 2026-11-28 |
| [Star Refrigeration](https://commercialheatpumpvendors.com/star-refrigeration/) | Water Source Neatpump | Water-to-water | 700 kW–10 MW thermal modular range | — | 130[1](https://www.star-ref.co.uk/products/heat-pumps/water-source-heat-pump-neatpump/ "Source: www.star-ref.co.uk (accessed 2026-11-28)") | R717 | 2026-11-28 |
| [Strebel Heating Technology](https://commercialheatpumpvendors.com/strebel/) | S-ASX-LPi | Air-to-water | 20.5–108 kW min-to-max range at A7/W35, across configurations | — | 68[1](https://strebel.co.uk/products/s-asx-lpi/ "Source: strebel.co.uk (accessed 2026-11-28)") | — | 2026-11-28 |
| [Swegon](https://commercialheatpumpvendors.com/swegon/) | EPSILON Zero Hi HP 30 | Air-to-water | 14–45 kW (family heating range) | — | 75[4](https://www.swegon.com/globalassets/digizuite/19000-en-epsilonzero_brochure_en.pdf "Source: www.swegon.com (accessed 2026-11-28)") | R290 | 2026-11-28 |
| [Thermonova](https://commercialheatpumpvendors.com/thermonova/) | Nova 110 | Air-to-water | 45–110 kW (Nova 110 range) | — | 70[1](https://www.thermonova.com/nova-series "Source: www.thermonova.com (accessed 2026-11-28)") | R290 | 2026-11-28 |
| [Trane](https://commercialheatpumpvendors.com/trane/) | Ascend ACX | Air-to-water | 1,000–2,500 MBH heating, Ascend ACX family | — | 62.8[1](https://www.trane.com/commercial/north-america/us/en/products-systems/chillers/air-cooled-chillers/ascend-air-to-water-heat-pump.html "Source: www.trane.com (accessed 2026-11-28)") | R454B | 2026-11-28 |
| [Turboden](https://commercialheatpumpvendors.com/turboden/) | Heat Pump to Steam | Waste heat-to-steam | Up to 15 t/h of steam at 2 bar(a), direct generation | — | — | — | 2026-11-28 |
| [Viessmann Climate Solutions](https://commercialheatpumpvendors.com/viessmann/) | Vitocal 200-A PRO | Air-to-water | 32, 64 and 128 kW rated heat output | — | 65[1](https://www.viessmann-climatesolutions.com/en/newsroom/solution-offering/start-of-production-vitocal-200-a-pro.html "Source: www.viessmann-climatesolutions.com (accessed 2026-11-28)") | — | 2026-11-28 |
| [WaterDrop by Small Planet Supply](https://commercialheatpumpvendors.com/waterdrop/) | Modular Droplets | Air-to-water | — | — | 65.6[1](https://www.waterdropsystems.com/ "Source: www.waterdropsystems.com (accessed 2026-11-28)") | R744 | 2026-11-28 |
| [Waterkotte](https://commercialheatpumpvendors.com/waterkotte/) | Industrial Line 8060.7 | Brine-to-water and Water-to-water | Up to 60 kW (catalog unit maximum) | — | — | R290 | 2026-11-28 |
| [WOLF](https://commercialheatpumpvendors.com/wolf/) | CHA-20/24-400V-M2 CS-e9-D2 | Air-to-water | 5.6–24.0 kW at A7/W35 (CHA 20/24 range) | — | 70[1](https://mediacenter.wolf.eu/de-de/pressemitteilungen/2025/cha-20-24-waermepumpe "Source: mediacenter.wolf.eu (accessed 2026-11-28)") | R290 | 2026-11-28 |

Featured slot open Put your company in front of engineers and building owners specifying heat pumps. [See terms](https://commercialheatpumpvendors.com/sponsor/)

Send your peak heating load, heat source, supply and return temperatures, project location, electrical supply and target delivery date.

## Request quotes at your design point

One brief, several replies: Commercial Heat Pump Vendors forwards it to the heat pump suppliers that fit and they answer you directly.

Brief received by Commercial Heat Pump Vendors. Matching heat pump suppliers reply to your inbox.

We couldn't send your request through Commercial Heat Pump Vendors. Check your email address and try again, or write to [hello@commercialheatpumpvendors.com](mailto:hello@commercialheatpumpvendors.com).

## Commercial heat pump buying questions

### How do I shortlist a commercial heat pump?

Start with the heat source and the delivery medium. Use your peak heating load, source temperature and required supply and return temperatures to request equipment selections.

### What should I include when requesting pricing?

Send the design load, source and delivery temperatures, site location, available voltage and preferred delivery date. Ask for equipment and installation as separate line items.

### What determines how much heat a unit can deliver?

Heating output depends on the entering source condition and required delivery temperature. Read each rated output together with its test point and ask for a selection at your design conditions.

### Where do I find model-level listings?

Open the certification and qualified-list guide to see the exact variant, issuing body and date. Find the full lookup link in each applicable vendor profile.

```json
{"@context":"https://schema.org","@graph":[{"@type":"WebSite","@id":"https://commercialheatpumpvendors.com/#website","name":"Commercial Heat Pump Vendors","url":"https://commercialheatpumpvendors.com/","description":"Shortlist commercial heat pumps by heat source, refrigerant and water temperature. Compare manufacturer ratings, open the evidence and request project quotes.","inLanguage":"en","publisher":{"@id":"https://commercialheatpumpvendors.com/#organization"}},{"@type":"Organization","@id":"https://commercialheatpumpvendors.com/#organization","name":"Commercial Heat Pump Vendors","url":"https://commercialheatpumpvendors.com/","email":"hello@commercialheatpumpvendors.com"},{"@type":"ItemList","@id":"https://commercialheatpumpvendors.com/#list","name":"Commercial heat pumps","numberOfItems":64,"itemListOrder":"https://schema.org/ItemListUnordered","itemListElement":[{"@type":"ListItem","position":1,"name":"A. O. Smith","url":"https://commercialheatpumpvendors.com/ao-smith/"},{"@type":"ListItem","position":2,"name":"Advansor","url":"https://commercialheatpumpvendors.com/advansor/"},{"@type":"ListItem","position":3,"name":"Aermec","url":"https://commercialheatpumpvendors.com/aermec/"},{"@type":"ListItem","position":4,"name":"Carrier","url":"https://commercialheatpumpvendors.com/carrier/"},{"@type":"ListItem","position":5,"name":"Clade Engineering Systems","url":"https://commercialheatpumpvendors.com/clade/"},{"@type":"ListItem","position":6,"name":"Clivet","url":"https://commercialheatpumpvendors.com/clivet/"},{"@type":"ListItem","position":7,"name":"Colmac WaterHeat","url":"https://commercialheatpumpvendors.com/colmac-waterheat/"},{"@type":"ListItem","position":8,"name":"COMBITHERM","url":"https://commercialheatpumpvendors.com/combitherm/"},{"@type":"ListItem","position":9,"name":"Copeland / Vilter","url":"https://commercialheatpumpvendors.com/copeland-vilter/"},{"@type":"ListItem","position":10,"name":"Daikin","url":"https://commercialheatpumpvendors.com/daikin/"},{"@type":"ListItem","position":11,"name":"ECO₂ Systems","url":"https://commercialheatpumpvendors.com/eco2-systems/"},{"@type":"ListItem","position":12,"name":"ecop Technologies","url":"https://commercialheatpumpvendors.com/ecop/"},{"@type":"ListItem","position":13,"name":"ELCO","url":"https://commercialheatpumpvendors.com/elco/"},{"@type":"ListItem","position":14,"name":"Energy Machines","url":"https://commercialheatpumpvendors.com/energy-machines/"},{"@type":"ListItem","position":15,"name":"Enerin","url":"https://commercialheatpumpvendors.com/enerin/"},{"@type":"ListItem","position":16,"name":"Everllence","url":"https://commercialheatpumpvendors.com/everllence/"},{"@type":"ListItem","position":17,"name":"Fenagy","url":"https://commercialheatpumpvendors.com/fenagy/"},{"@type":"ListItem","position":18,"name":"Flow Environmental Systems","url":"https://commercialheatpumpvendors.com/flow-environmental/"},{"@type":"ListItem","position":19,"name":"Friotherm","url":"https://commercialheatpumpvendors.com/friotherm/"},{"@type":"ListItem","position":20,"name":"Futraheat","url":"https://commercialheatpumpvendors.com/futraheat/"},{"@type":"ListItem","position":21,"name":"Galletti","url":"https://commercialheatpumpvendors.com/galletti/"},{"@type":"ListItem","position":22,"name":"GENERAL (formerly Fujitsu General)","url":"https://commercialheatpumpvendors.com/general-airstage/"},{"@type":"ListItem","position":23,"name":"GKT","url":"https://commercialheatpumpvendors.com/gkt/"},{"@type":"ListItem","position":24,"name":"HEATEN","url":"https://commercialheatpumpvendors.com/heaten/"},{"@type":"ListItem","position":25,"name":"HiRef","url":"https://commercialheatpumpvendors.com/hiref/"},{"@type":"ListItem","position":26,"name":"Intellihot","url":"https://commercialheatpumpvendors.com/intellihot/"},{"@type":"ListItem","position":27,"name":"Johnson Controls / Sabroe","url":"https://commercialheatpumpvendors.com/johnson-controls-sabroe/"},{"@type":"ListItem","position":28,"name":"Keyter","url":"https://commercialheatpumpvendors.com/keyter/"},{"@type":"ListItem","position":29,"name":"Kobelco","url":"https://commercialheatpumpvendors.com/kobelco/"},{"@type":"ListItem","position":30,"name":"Laars Heating Systems","url":"https://commercialheatpumpvendors.com/laars/"},{"@type":"ListItem","position":31,"name":"LG Electronics","url":"https://commercialheatpumpvendors.com/lg/"},{"@type":"ListItem","position":32,"name":"Lochinvar","url":"https://commercialheatpumpvendors.com/lochinvar/"},{"@type":"ListItem","position":33,"name":"Lync by Watts","url":"https://commercialheatpumpvendors.com/lync/"},{"@type":"ListItem","position":34,"name":"Mayekawa","url":"https://commercialheatpumpvendors.com/mayekawa/"},{"@type":"ListItem","position":35,"name":"Mitsubishi Electric","url":"https://commercialheatpumpvendors.com/mitsubishi-electric/"},{"@type":"ListItem","position":36,"name":"Mitsubishi Heavy Industries Thermal Systems","url":"https://commercialheatpumpvendors.com/mitsubishi-heavy-industries/"},{"@type":"ListItem","position":37,"name":"MTA","url":"https://commercialheatpumpvendors.com/mta/"},{"@type":"ListItem","position":38,"name":"Multistack","url":"https://commercialheatpumpvendors.com/multistack/"},{"@type":"ListItem","position":39,"name":"Nyle Water Heating Systems","url":"https://commercialheatpumpvendors.com/nyle/"},{"@type":"ListItem","position":40,"name":"OCHSNER Energietechnik","url":"https://commercialheatpumpvendors.com/ochsner/"},{"@type":"ListItem","position":41,"name":"Oilon","url":"https://commercialheatpumpvendors.com/oilon/"},{"@type":"ListItem","position":42,"name":"Olvondo Technology","url":"https://commercialheatpumpvendors.com/olvondo-technology/"},{"@type":"ListItem","position":43,"name":"Panasonic","url":"https://commercialheatpumpvendors.com/panasonic/"},{"@type":"ListItem","position":44,"name":"PILLER","url":"https://commercialheatpumpvendors.com/piller/"},{"@type":"ListItem","position":45,"name":"Qpinch","url":"https://commercialheatpumpvendors.com/qpinch/"},{"@type":"ListItem","position":46,"name":"Qvantum","url":"https://commercialheatpumpvendors.com/qvantum/"},{"@type":"ListItem","position":47,"name":"Rank ORC","url":"https://commercialheatpumpvendors.com/rank/"},{"@type":"ListItem","position":48,"name":"Rheem","url":"https://commercialheatpumpvendors.com/rheem/"},{"@type":"ListItem","position":49,"name":"Rhoss","url":"https://commercialheatpumpvendors.com/rhoss/"},{"@type":"ListItem","position":50,"name":"Samsung","url":"https://commercialheatpumpvendors.com/samsung/"},{"@type":"ListItem","position":51,"name":"SCM Frigo","url":"https://commercialheatpumpvendors.com/scm-frigo/"},{"@type":"ListItem","position":52,"name":"Siemens Energy","url":"https://commercialheatpumpvendors.com/siemens-energy/"},{"@type":"ListItem","position":53,"name":"SKADEC","url":"https://commercialheatpumpvendors.com/skadec/"},{"@type":"ListItem","position":54,"name":"Spilling","url":"https://commercialheatpumpvendors.com/spilling/"},{"@type":"ListItem","position":55,"name":"Star Refrigeration","url":"https://commercialheatpumpvendors.com/star-refrigeration/"},{"@type":"ListItem","position":56,"name":"Strebel Heating Technology","url":"https://commercialheatpumpvendors.com/strebel/"},{"@type":"ListItem","position":57,"name":"Swegon","url":"https://commercialheatpumpvendors.com/swegon/"},{"@type":"ListItem","position":58,"name":"Thermonova","url":"https://commercialheatpumpvendors.com/thermonova/"},{"@type":"ListItem","position":59,"name":"Trane","url":"https://commercialheatpumpvendors.com/trane/"},{"@type":"ListItem","position":60,"name":"Turboden","url":"https://commercialheatpumpvendors.com/turboden/"},{"@type":"ListItem","position":61,"name":"Viessmann Climate Solutions","url":"https://commercialheatpumpvendors.com/viessmann/"},{"@type":"ListItem","position":62,"name":"WaterDrop by Small Planet Supply","url":"https://commercialheatpumpvendors.com/waterdrop/"},{"@type":"ListItem","position":63,"name":"Waterkotte","url":"https://commercialheatpumpvendors.com/waterkotte/"},{"@type":"ListItem","position":64,"name":"WOLF","url":"https://commercialheatpumpvendors.com/wolf/"}]},{"@type":"Dataset","@id":"https://commercialheatpumpvendors.com/#dataset","name":"Commercial heat pumps","description":"Shortlist commercial heat pumps by heat source, refrigerant and water temperature. Compare manufacturer ratings, open the evidence and request project quotes.","url":"https://commercialheatpumpvendors.com/","dateModified":"2026-11-28","creator":{"@id":"https://commercialheatpumpvendors.com/#organization"},"isAccessibleForFree":true,"variableMeasured":["Vendor name","Official website","Headquarters","Published company location","Model or family","Heat path","Published heat output","Rated heat output (kW)","Rating conditions","Published delivery temperature (°C)","Temperature conditions","Refrigerant","Documented use","Configuration","Certification observation","ENERGY STAR certification date","Qualified-list observation","Second-source evidence","Delivery medium","Match scope"],"size":"64 records","license":"https://creativecommons.org/licenses/by/4.0/","distribution":[{"@type":"DataDownload","encodingFormat":"application/json","contentUrl":"https://commercialheatpumpvendors.com/data.json"},{"@type":"DataDownload","encodingFormat":"text/csv","contentUrl":"https://commercialheatpumpvendors.com/data.csv"}]}]}
```