Which commercial hot-water heat pumps use CO₂?

13 vendors document an R744 heat pump that delivers hot water. The models serve different loads, from central domestic hot water to district heating. Compare the published water temperature and operating conditions to decide which vendors should quote your duty. Examples include Advansor, Clade Engineering Systems and ECO₂ Systems.

Field definitions and sources Full vendor table

AdvansorValueBox 600Air-to-water——953Family maximum; published 600 kW installation uses 40/80 °C water at −5 °C ambient2026-11-28
Clade Engineering SystemsAcer 2Air-to-water1302A7/W70702—2026-11-28
ECO₂ SystemsSANCO₂ GS5-45HPCAir-to-water——62.81145 °F water-temperature setting in the GS5 installation manual2026-11-28
EverllenceTCC HPU28Water-to-water9,6701Source 10 °C; sink supply/return 110/40 °C1501—2026-11-28
FenagyH-600 (H-range)Air-to-water and Water-to-water——851Below 45 °C return (family application guidance)2026-11-28
Flow Environmental SystemsANSWR Model CAir- or water-to-water66.82Air-to-water boiler mode at 47 °F ambient, 140 °F entering / 180 °F leaving water82.22Boiler-mode leaving water, with 140 °F entering water in the cited table2026-11-28
IntellihotElectron iE6Air-to-water————2026-11-28
Laars Heating SystemsE-Therm ECHV0325Air-to-water952AHRI 1300 test conditions, as stated by Laars——2026-11-28
Lync by WattsAegis A 250Air-to-water61.5325 °C ambient at 60% RH and primary loop 20 °C entering / 80 °C leaving823Primary outlet range 60–82 °C; storage range depends on heat exchanger module2026-11-28
Mayekawaunimo AWAir-to-water74165 °C leaving water, North American AW specification901—2026-11-28
Mitsubishi ElectricHeat2O QAHV-N136TAU-HPBAir-to-water40227°C dry-bulb / 21.8°C wet-bulb air, 21°C entering / 49°C leaving water (208V brochure rating)71.12Secondary potable side, depending on derated heat pump capacity and balanced low flow2026-11-28
SCM FrigoSMART SHP W110Water-to-water1094Maximum at brine 0/−3 °C and water 40/70 °C854—2026-11-28
WaterDrop by Small Planet SupplyModular DropletsAir-to-water——65.61—2026-11-28

Send your peak heating load, heat source, supply and return temperatures, project location, electrical supply and target delivery date.

Request quotes at your design point

One brief, several replies: Commercial Heat Pump Vendors forwards it to the heat pump suppliers that fit and they answer you directly.

Brief received by Commercial Heat Pump Vendors. Matching heat pump suppliers reply to your inbox.

Sending shares your request and contact details with matching heat pump suppliers through Commercial Heat Pump Vendors so they can reply. Privacy policy

Questions for your RFQ

What refrigerant designation should I look for?

Look for R744, the designation for carbon dioxide used as a refrigerant.

Which water temperatures should my quote state?

Specify entering and leaving water temperatures at full demand and the return temperature under recirculation. For indirect systems, ask for both primary and potable conditions.

What should I compare when a vendor includes storage?

Compare recovery output at the same conditions, usable storage volume and the control sequence for the whole system.