Which commercial hot-water heat pumps use CO₂?
13 vendors document an R744 heat pump that delivers hot water. The models serve different loads, from central domestic hot water to district heating. Compare the published water temperature and operating conditions to decide which vendors should quote your duty. Examples include Advansor, Clade Engineering Systems and ECO₂ Systems.
| Advansor | ValueBox 600 | Air-to-water | — | — | 953 | Family maximum; published 600 kW installation uses 40/80 °C water at −5 °C ambient | 2026-11-28 |
|---|---|---|---|---|---|---|---|
| Clade Engineering Systems | Acer 2 | Air-to-water | 1302 | A7/W70 | 702 | — | 2026-11-28 |
| ECO₂ Systems | SANCO₂ GS5-45HPC | Air-to-water | — | — | 62.81 | 145 °F water-temperature setting in the GS5 installation manual | 2026-11-28 |
| Everllence | TCC HPU28 | Water-to-water | 9,6701 | Source 10 °C; sink supply/return 110/40 °C | 1501 | — | 2026-11-28 |
| Fenagy | H-600 (H-range) | Air-to-water and Water-to-water | — | — | 851 | Below 45 °C return (family application guidance) | 2026-11-28 |
| Flow Environmental Systems | ANSWR Model C | Air- or water-to-water | 66.82 | Air-to-water boiler mode at 47 °F ambient, 140 °F entering / 180 °F leaving water | 82.22 | Boiler-mode leaving water, with 140 °F entering water in the cited table | 2026-11-28 |
| Intellihot | Electron iE6 | Air-to-water | — | — | — | — | 2026-11-28 |
| Laars Heating Systems | E-Therm ECHV0325 | Air-to-water | 952 | AHRI 1300 test conditions, as stated by Laars | — | — | 2026-11-28 |
| Lync by Watts | Aegis A 250 | Air-to-water | 61.53 | 25 °C ambient at 60% RH and primary loop 20 °C entering / 80 °C leaving | 823 | Primary outlet range 60–82 °C; storage range depends on heat exchanger module | 2026-11-28 |
| Mayekawa | unimo AW | Air-to-water | 741 | 65 °C leaving water, North American AW specification | 901 | — | 2026-11-28 |
| Mitsubishi Electric | Heat2O QAHV-N136TAU-HPB | Air-to-water | 402 | 27°C dry-bulb / 21.8°C wet-bulb air, 21°C entering / 49°C leaving water (208V brochure rating) | 71.12 | Secondary potable side, depending on derated heat pump capacity and balanced low flow | 2026-11-28 |
| SCM Frigo | SMART SHP W110 | Water-to-water | 1094 | Maximum at brine 0/−3 °C and water 40/70 °C | 854 | — | 2026-11-28 |
| WaterDrop by Small Planet Supply | Modular Droplets | Air-to-water | — | — | 65.61 | — | 2026-11-28 |
Send your peak heating load, heat source, supply and return temperatures, project location, electrical supply and target delivery date.
Request quotes at your design point
One brief, several replies: Commercial Heat Pump Vendors forwards it to the heat pump suppliers that fit and they answer you directly.
Brief received by Commercial Heat Pump Vendors. Matching heat pump suppliers reply to your inbox.
We couldn't send your request through Commercial Heat Pump Vendors. Check your email address and try again, or write to hello@commercialheatpumpvendors.com.
Questions for your RFQ
What refrigerant designation should I look for?
Look for R744, the designation for carbon dioxide used as a refrigerant.
Which water temperatures should my quote state?
Specify entering and leaving water temperatures at full demand and the return temperature under recirculation. For indirect systems, ask for both primary and potable conditions.
What should I compare when a vendor includes storage?
Compare recovery output at the same conditions, usable storage volume and the control sequence for the whole system.