Which commercial heat pumps supply water at 80 °C or higher?

19 vendors document a catalogued water delivery temperature of at least 80 °C for an equipment family or model. Use the cited operating envelope to identify candidates and ask for net heating output at your source temperature and required return temperature. Examples include Advansor, Everllence and Fenagy.

Field definitions and sources Full vendor table

AdvansorValueBox 600Air-to-water953Family maximum; published 600 kW installation uses 40/80 °C water at −5 °C ambientR7442026-11-28
EverllenceTCC HPU28Water-to-water1501—R7442026-11-28
FenagyH-600 (H-range)Air-to-water and Water-to-water851Below 45 °C return (family application guidance)R7442026-11-28
Flow Environmental SystemsANSWR Model CAir- or water-to-water82.22Boiler-mode leaving water, with 140 °F entering water in the cited tableR7442026-11-28
FriothermUnitopWater-to-water1201——2026-11-28
GallettiWBEWater-to-water901Typically 45 °C source water for high-temperature productionR515B2026-11-28
HEATENHeatBooster HBL4-W/WWater-to-water2001—Hydrocarbon or HFO configuration2026-11-28
HiRefKSWWater-to-water80280 °C with a medium-temperature water source—2026-11-28
Johnson Controls / SabroeHitemHPWaste heat-to-water1221—R600 / R600a2026-11-28
Lync by WattsAegis A 250Air-to-water823Primary outlet range 60–82 °C; storage range depends on heat exchanger moduleR7442026-11-28
Mayekawaunimo AWAir-to-water901—R7442026-11-28
Mitsubishi Heavy Industries Thermal SystemsETW-SWater-to-water1301—R134a2026-11-28
OCHSNER EnergietechnikIWWDS 430 R4bWater-to-water1301—R1233zd2026-11-28
OilonChillHeat P30–P450Waste heat-to-water1203—R134a for B0/W35 range figures2026-11-28
Rank ORCHP (HTHP series)Brine-to-water1501Portal lists 25–110 °C source envelope, with separate flow limitsR1233zd(E) / R1336mzz(Z) / R245fa2026-11-28
SCM FrigoSMART SHP W110Water-to-water854—R7442026-11-28
Siemens EnergyHigh-temperature industrial heat pumpWaste heat-to-water1501——2026-11-28
SKADECSH.F. R600Water-to-water903—R600a2026-11-28
Star RefrigerationWater Source NeatpumpWater-to-water1301—R7172026-11-28

Send your peak heating load, heat source, supply and return temperatures, project location, electrical supply and target delivery date.

Request quotes at your design point

One brief, several replies: Commercial Heat Pump Vendors forwards it to the heat pump suppliers that fit and they answer you directly.

Brief received by Commercial Heat Pump Vendors. Matching heat pump suppliers reply to your inbox.

Sending shares your request and contact details with matching heat pump suppliers through Commercial Heat Pump Vendors so they can reply. Privacy policy

Questions for your RFQ

What is the temperature threshold for this table?

The table uses a published water delivery figure of 80 °C or higher. Follow the value to the product document for the applicable operating conditions.

What should I ask for on a boiler retrofit?

Request the net heat output at your required supply temperature, design return temperature and coldest source condition. Ask for the control sequence at part load.

Which delivery temperature should I use with an indirect water heater?

Use the temperature required on the load side of the heat exchanger. Ask the vendor to state the primary-loop and load-side temperatures separately.