Which commercial heat pumps supply water at 80 °C or higher?
19 vendors document a catalogued water delivery temperature of at least 80 °C for an equipment family or model. Use the cited operating envelope to identify candidates and ask for net heating output at your source temperature and required return temperature. Examples include Advansor, Everllence and Fenagy.
| Advansor | ValueBox 600 | Air-to-water | 953 | Family maximum; published 600 kW installation uses 40/80 °C water at −5 °C ambient | R744 | 2026-11-28 |
|---|---|---|---|---|---|---|
| Everllence | TCC HPU28 | Water-to-water | 1501 | — | R744 | 2026-11-28 |
| Fenagy | H-600 (H-range) | Air-to-water and Water-to-water | 851 | Below 45 °C return (family application guidance) | R744 | 2026-11-28 |
| Flow Environmental Systems | ANSWR Model C | Air- or water-to-water | 82.22 | Boiler-mode leaving water, with 140 °F entering water in the cited table | R744 | 2026-11-28 |
| Friotherm | Unitop | Water-to-water | 1201 | — | — | 2026-11-28 |
| Galletti | WBE | Water-to-water | 901 | Typically 45 °C source water for high-temperature production | R515B | 2026-11-28 |
| HEATEN | HeatBooster HBL4-W/W | Water-to-water | 2001 | — | Hydrocarbon or HFO configuration | 2026-11-28 |
| HiRef | KSW | Water-to-water | 802 | 80 °C with a medium-temperature water source | — | 2026-11-28 |
| Johnson Controls / Sabroe | HitemHP | Waste heat-to-water | 1221 | — | R600 / R600a | 2026-11-28 |
| Lync by Watts | Aegis A 250 | Air-to-water | 823 | Primary outlet range 60–82 °C; storage range depends on heat exchanger module | R744 | 2026-11-28 |
| Mayekawa | unimo AW | Air-to-water | 901 | — | R744 | 2026-11-28 |
| Mitsubishi Heavy Industries Thermal Systems | ETW-S | Water-to-water | 1301 | — | R134a | 2026-11-28 |
| OCHSNER Energietechnik | IWWDS 430 R4b | Water-to-water | 1301 | — | R1233zd | 2026-11-28 |
| Oilon | ChillHeat P30–P450 | Waste heat-to-water | 1203 | — | R134a for B0/W35 range figures | 2026-11-28 |
| Rank ORC | HP (HTHP series) | Brine-to-water | 1501 | Portal lists 25–110 °C source envelope, with separate flow limits | R1233zd(E) / R1336mzz(Z) / R245fa | 2026-11-28 |
| SCM Frigo | SMART SHP W110 | Water-to-water | 854 | — | R744 | 2026-11-28 |
| Siemens Energy | High-temperature industrial heat pump | Waste heat-to-water | 1501 | — | — | 2026-11-28 |
| SKADEC | SH.F. R600 | Water-to-water | 903 | — | R600a | 2026-11-28 |
| Star Refrigeration | Water Source Neatpump | Water-to-water | 1301 | — | R717 | 2026-11-28 |
Send your peak heating load, heat source, supply and return temperatures, project location, electrical supply and target delivery date.
Request quotes at your design point
One brief, several replies: Commercial Heat Pump Vendors forwards it to the heat pump suppliers that fit and they answer you directly.
Brief received by Commercial Heat Pump Vendors. Matching heat pump suppliers reply to your inbox.
We couldn't send your request through Commercial Heat Pump Vendors. Check your email address and try again, or write to hello@commercialheatpumpvendors.com.
Questions for your RFQ
What is the temperature threshold for this table?
The table uses a published water delivery figure of 80 °C or higher. Follow the value to the product document for the applicable operating conditions.
What should I ask for on a boiler retrofit?
Request the net heat output at your required supply temperature, design return temperature and coldest source condition. Ask for the control sequence at part load.
Which delivery temperature should I use with an indirect water heater?
Use the temperature required on the load side of the heat exchanger. Ask the vendor to state the primary-loop and load-side temperatures separately.